Skip to content
Welcome to the next generation MIKE+ Documentation

Linear Reservoir (C1 and C2)

The Linear Reservoir model (Model C) is a surface runoff model with minimum data requirements. The runoff computation is based on a comprehensive treatment of hydrological losses (including infiltration) and runoff routing by the linear reservoir principle. Technical details can be found in the MIKE 1D Reference Manual.

MIKE+ includes this model in two versions: C1 and C2. These are variants of the same model, and are used as national standards in the Netherlands and France, respectively.

Linear Reservoir C1 Model Data

modelC1.jpg 

Figure: The Linear Reservoir C1 Model tab

A full overview of the editor fields and corresponding attributes for the Linear Reservoir C1 model is provided in the table below.

Edit field Description Used or required by simulations Field name in datastructure
Effective Area Contributing area Yes ModelC1EffectiveArea
Use Parameter Set Reference to a set of model parameters to be used for the current catchment Yes ModelC1ParCID
Use Local Parameters Allows for local use of individual parameters Optional ModelC1LocalNo
Time Constant Local value of the time constant Optional ModelC1TimeConst
Init. Loss Local value of the initial loss Optional ModelC1Iloss

Table: Overview of the Linear Reservoir C1 attributes (Table msm_Catchment)

Linear Reservoir C2 Model Data

modelC2.jpg 

Figure: The Linear Reservoir C2 Model tab

A full overview of the editor fields and corresponding Linear Reservoir C2 model attributes is provided in the table below.

Edit field Description Used or required by simulations Field name in datastructure
Length Characteristic length of the catchment Yes ModelCLength
Slope Representative slope of the catchment Yes ModelCSlope
Imperviousness Impervious area as a percentage of the actual model area. For values >= 20%, the catchment is an urban catchment. For values < 20%, the catchment is a rural one. Yes ModelC2ImperviousArea
Use Parameter Set Reference to a set of model parameters to be used for the current catchment Yes ModelC2ParCID
Use Local Parameters Allows for local use of individual parameters Optional ModelC2LocalNo
Reduction Factor Local value of the hydrological reduction factor Optional ModelC2RedFactor
Init. Loss Local value of the initial loss Optional ModelC2Iloss
Lag Time Local value of the lag time. If this field is left empty for a catchment defined with local parameters, then a lag time of 5 minutes is used in the simulation Optional ModelC2LagTime

Table: Overview of the Linear Reservoir C2 attributes (Table msm_Catchment)

Parameters Linear Reservoir

The Linear Reservoir model uses a number of parameters. For practical reasons, these parameters have been grouped in parameter sets, which, in turn, can be associated with certain catchments. This means the entire model setup can be established with a very small amount of information, while still allowing for full spatial variation of model parameters for individual catchments through the application of local values.

New parameter sets can be inserted and values of individual parameters can be edited in the Parameters Linear Reservoir Editor. This can be activated via Catchments|Parameters Linear Reservoir.

MIKE+ comes with a Default parameter set (-DEFAULT-). The User can insert any number of parameter sets and edit them as needed.

C1&2_ParameterSettings.png 

Figure: The ‘Parameters linear reservoir’ editor for Dutch and French reservoir models

A full overview of the editor fields and corresponding database attributes is provided in the table below.

Edit field Description Used or required by simulations Field name in datastructure
Parameter Set ID Parameter set identifier Yes MUID
C1/C2 Toggle for editor setting for model C1 and C2, respectively Yes -
Initial Loss Local value of the initial loss Yes Iloss
Time Constant Local value of the time constant Optional, model C1 only CTime
Reduction Factor Local value of the hydrological reduction factor Optional, model C2 only RFactor
Lag Time Local value of the lag time. If this field is left empty, catchments defined with this parameter set will use a lag time of 5 minutes in the simulation Optional, model C2 only LagTime
Infiltration Toggle for switching ON and OFF calculation of infiltration Optional InfitrNo
Maximum Horton´s Infiltration Capacity Maximum infiltration capacity Optional, if infiltration included MaxCap
Minimum Horton´s infiltration capacity Minimum infiltration capacity Optional, if infiltration included MinCap
Wet Condition Time Constant Infiltration time constant for wet conditions Optional, if infiltration included WetCond
Dry Condition Time Constant Infiltration time constant for dry conditions Optional, if infiltration included DryCond

Table: Overview of the Linear Reservoir Parameter Set attributes (Table msm_HParC)