Initial Loading

Define initial pollutant quantities in catchments via the SWMM Initial Loading editor. The editor organizes data into the following groups:

  • Identification: Initial load setup ID information.
  • Loading Properties: Initial buildup data.

SWMM_InitialLoading.png 

Figure: The SWMM Initial Loading editor

Edit field Description Used or required by simulations Field name in datastructure
ID Initial loading setup ID Yes MUID
Description Optional description of initial loading record No Description
Catchment ID ID of catchment for which initial buildup is specified Yes CatchID
Pollutant ID ID of pollutant Yes PollutantID
Initial Buildup Amount of initial pollutant buildup Yes InitBuildUp

Table: Edit fields in the Initial Loading editor (mss_Loading)